FUSION Operations Manual Chapter 7: System Operations (Rev.2)

Page 7-17

Data No.16 SNUG Torque

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0

Snug Torque is only available as a control start point when [00: Fastening Mode] is set

for Angle Control method.

Angle (of rotation) Judgment is conducted from Snug Torque to Fastening end when this

torque value is achieved, for all fastening methods. The Angle when this torque value is

achieved is considered the 0° start point for judgment.

(Example.) When [16: SNUG Torque] is 10Nm, [22: Standard Angle] is 90°.

Data No.17 Threshold Torque

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0

Start point for 1

st

Torque Rate monitoring

Torque

Angle

90°

Judgment torque

16 SNUG

10Nm

22 Standard Angle

All values related to Angles are referenced from [16:SNUG Torque]

Angle

Torque

30 Rate 1 Low Limit

31 Rate 1 High Limit

15 1ST

17 Threshold

If 1

st

Torque Rate monitoring is not required, [17:Threshold Torque] should be set

the same or higher than [10: Calibration Torque]