7.5 Optional Real Time Clock Module

The Fusion system stores 10000 cycles of fastening results in its flash memory. In order to

add a Date/Time stamp to this data, an optional Real Time Clock module can be added to the

controller. This module is added into the back of the controller inside of the access panel at

the upper right side.

When this clock module is added, the date & time will be attached to the stored data every

cycle. This function is available in Firmware version 2.20 or later

The AFC software will be required for restoring stored data from controller.

Clock module model :

ANG-RTC

Backup power source :

Electric double layer capacitor

Backup memory duration :

Approx. 10000 hours

Backup power charge time

Approx. 1hour

If the controller power is turned off for more than 2 months, the clock backup power will be

lost & the time settings will be lost.

The Clock can be set using the front display & keypad the same method as changing para-

meter data. See the table below for parameter numbers.

Work #

Data #

Item

Example

00

30

Year ‘yyyy’

‘2005’ Year 2005

00

31

Month & Date ‘mmdd’

‘0131’ January 31st

00

32

Hour & Minute ‘hhmm’

‘1759’ 17:59

00

33

Seconds ‘00ss’

‘0020’ 20 second

Seconds will be set as ‘00’ when Hour & Time (Data # 32) is changed.

Note: Clock may be off approx. 10 seconds / month. Adjust as required.