Chapter 4: System Setup and Wiring

Page 4-20

4.8.3 Rear Panel RS232 Standard Communication Protocol

Communication protocol from the rear panel RS232 port is as follows;

Speed

:

9600bps

Parity

:

None

Data Bits

:

8 Bit

Start Bit

:

1 Bit

Stop Bit

:

2 Bit

Error Control

: None

The data format from the Fusion system is a formatted ASCII output. This can be connected

to a serial printer, computer or other peripheral device. 214 bytes of data is output per fas-

tening using the Standard Format. The data format is described below.

Byte

Description

Example

ASCII Data

69 1

st

Rate Incr. Ang. 32H

2

70 2

nd

Rate Incr. TQ. 30H

0

71 2

nd

Rate Incr. TQ. 30H

0

72 2

nd

Rate Incr. TQ. 32H

2

73 2

nd

Rate Incr. TQ. 35H

5

74 2

nd

Rate Incr. Ang. 30H

0

75 2

nd

Rate Incr. Ang. 31H

1

76 2

nd

Rate Incr. Ang. 30H

0

77 2

nd

Rate Incr. Ang. 30H

0

78 3

rd

Rate Incr. TQ. 30H

0

79 3

rd

Rate Incr. TQ. 30H

0

80 3

rd

Rate Incr. TQ. 31H

1

81 3

rd

Rate Incr. TQ. 30H

0

82 3

rd

Rate Incr. Ang. 30H

0

83 3

rd

Rate Incr. Ang. 30H

0

84 3

rd

Rate Incr. Ang. 32H

2

85 3

rd

Rate Incr. Ang. 31H

1

86

1

st

Time

30H

0

87

1

st

Time

30H

0

88

1

st

Time

36H

6

89

1

st

Time

35H

5

90

2

nd

Time

30H

0

91

2

nd

Time

30H

0

92

2

nd

Time

32H

2

93

2

nd

Time

37H

7

94

Rundown Revs

30H

0

95

Rundown Revs

31H

1

96

Rundown Revs

31H

1

97

Rundown Revs

35H

5

98

Offset Torque

30H

0

99

Offset Torque

30H

0

100

Offset Torque

30H

0

101

Offset Torque

30H

0

102 Fastening Mode

5

30H

0

Byte

Description

Example

ASCII Data

1

Start Of Text

02H

2

Parameter No.

20H

3

Parameter No.

31H

1

4

Clock – Year*

30H

0

5

Clock – Year*

37H

7

6

/

2FH

/

7

Clock – Month*

30H

0

8

Clock – Month*

38H

8

9

/

2FH

/

10

Clock – Day*

31H

1

11

Clock – Day*

35H

5

12

Time – Hour*

31H

1

13

Time – Hour*

32H

2

14

:

3AH

:

15

Time – Minute*

34H

4

16

Time – Minute*

35H

5

17

:

3AH

:

18

Time – Second*

33H

3

19

Time – Second*

30H

0

20

Spindle Number

30H

0

21

Spindle Number

31H

1

22

Judgment Flag

1

4FH

O

23

Judgment Flag

1

30H

0

24

Judgment Flag

1

30H

0

25

Judgment Flag

1

30H

0

26

Judgment Flag

1

30H

0

27

Judgment Flag

1

30H

0

28

Batch Count

30H

0

29

Batch Count

34H

4

30

Torque Unit

2

30H

0

31

Torque Decimal

3

32H

2

32

Rate Decimal

3

33H

3

33

Cycle Count

31H

1

34

Cycle Count

33H

3

Byte

Description

Example

ASCII Data

35

Cycle Count

35H

5

36

Cycle Count

37H

7

37

Peak Torque

31H

1

38

Peak Torque

39H

9

39

Peak Torque

39H

9

40

Peak Torque

39H

9

41

Final Torque

31H

1

42

Final Torque

39H

9

43

Final Torque

39H

9

44

Final Torque

39H

9

45

Final Angle

31H

1

46

Final Angle

39H

9

47

Final Angle

39H

9

48

Final Angle

39H

9

49

1

st

Rate

31H

1

50

1

st

Rate

39H

9

51

1

st

Rate

39H

9

52

1

st

Rate

39H

9

53

2

nd

Rate

31H

1

54

2

nd

Rate

39H

9

55

2

nd

Rate

39H

9

56

2

nd

Rate

39H

9

57

3

rd

Rate

31H

1

58

3

rd

Rate

39H

9

59

3

rd

Rate

39H

9

60

3

rd

Rate

39H

9

61

Rate Sign Flag

4

30H

0

62 1

st

Rate Incr. TQ. 30H

0

63 1

st

Rate Incr. TQ. 30H

0

64 1

st

Rate Incr. TQ.

32H

2

65 1

st

Rate Incr. TQ.

30H

0

66 1

st

Rate Incr. Ang.

30H

0

67 1

st

Rate Incr. Ang. 31H

1

68 1

st

Rate Incr. Ang. 32H

2