FEC FUSIONE-HS-2 User Manual

Page 88

Advertising
background image

Chapter 4: System Setup and Wiring

Page 4-50

Configuration

FEC DeviceNet I/O is pre-configured according to the I/O Signal Map (See below). Configu-

ration of the DeviceNet Master MUST match the size configuration of the FEC DeviceNet

slave or the network will not connect/operate properly. In the DeviceNet Master set-up using

RSNetworx, set the Input/Output length using the “Polled” option. When setting the Device-

Net Master I/O configuration, Input size refers to FEC output size (ie. Accept, Reject, Busy,

etc.) and Output size refers to FEC inputs (ie. Start, Stop, Reset, etc.). See the below

screen shots of this configuration using RSNetworx.

DeviceNet Interface Connections

Pin No.

Signal

Wire Color

1

V-

Black

2

CAN_L

Blue

3

Drain/Shield

4

CAN_H

White

5

V+

Red

Termination

Termination of the DeviceNet network requires a terminating resistor at each end of the net-

work. These resistors should have a value of 121 ohms.

See “Termination”