FEC FUSIONE-HS-2 User Manual

Page 26

Advertising
background image

Chapter 2: Specifications

Page 2-4

2.3 Controller Unit Specifications

Controller Model

HFC-EC-16

Motor Model

RM80, RM50

Controller Supply Voltage

Single Phase 100~ 230 VAC 50/60/Hz +/- 10%

Power Consumption (Running)

95 watt/hour @ 99% Capacity / 50% Duty

Power Consumption (Idle)

37 watt/Hour

Inrush current @ Power on

11A

If the equipment is powered on and off repeatedly, internal circuit protection devices

may trip due to high in-rush current overload, and the Controller will not function until

it is cleared (powered off).

(It may take up to five minutes of “off” time to clear the self-

protection circuit.)

Controller Processor:

32-bit RISC (Reduced Instruction Set CPU)

Parameter / Firmware Storage:

Flash ROM

Fastening Data Storage:

More than 10,000 cycles (stored in flash)

Fastening Method:

Torque and Angle, 1 ~ 3 step fastening

Torque Rate Calculation:

3

ranges

Data communications:

(1) RS232 – Front Panel - Input/output – Programming and Data collection

(1) RS232 – Rear Panel – Output – Printer or data collection device.

(1) T/A MON – Front Panel – Output – analog Torque and Angle analysis.

(1) Discrete I/O – Rear panel - Control and PLC interface

(1) Real Time Clock Connection

(1) Optional Ethernet – Output - Data collection

(1) Optional Fieldbus – Input/Output – Control and PLC interface

Caution