Data No.55 Not Used

Data No.56 Not Used

Data No.60 Freerun Revolutions

[rev]

Setting range: 0 ~ 99.9

Sets the number of revolutions the system will run from the beginning of the fastening operation until

[51:Freerun Speed] is no longer needed.

Override shifts to [52: Slow Down Speed] when [14:Speed Change Torque] is sensed.

Data No.61 Torque Inhibit Revolutions

[rev]

Setting range: 0 ~ 99.9

For operation that require large starting torque.

Duration for ignoring the Torque value sensed at Fastening start due to inertia. When the initial Tor-

que exceeds the [19: Torque Inhibit Limit] during [61: Torque Inhibit Revolutions] an ABNORMAL will

be generated and fastening will end.

Data No.62 Not Used
Data No.63 Not Used

Data No.64 Not Used

Data No.68 Not Used

Data No.69 Not Used

Data No.70 Full Scale Current

[A]

Data No.71 High Current Limit

[A]

Data No.72 Low Current Limit

[A]

Data No.73 Fastening Current Limit

[A]

Setting range: 0 ~ 12

Used as a redundant check of the fastening process. Please contact FEC Inc. for assistance.

Unit Type

Tool Type

Full Scale

Current [A]

High Current

Limit [A]

Low Current

Limit [A]

Fastening

Current [A]

HFC-EC-16

HFT

12.0 max

12.0 max

0.0

12.0 max

Data No.74 Accept Batch Count

Setting Range: 0 – 99

Used to set the number of accepts for WORK ACCEPT. Setting “0” disables function.

Data No.80 CW Stop Angle (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 360

Used to set the swing stop angle in the CW direction. This is the angle the pistol will swing up to be-

fore shutting off. Setting “180” disables function.

Data No.81 CW Swing Pause Angle (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 360

Used to set the swing Pause angle in the CW direction.

Data No.82 CW Swing Stop Servo Lock Time (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 1000

Used to set the swing stop servo lock time in the CW direction.