Test Setup - Test Configurator, Timer, and System

98

FTB-700G/800 Series

1588 PTP

GM Info

Note: Only available when Grand Master clock information is available.

The Grand Master Information window displays the decoded clock
information.

Identity report the 8-byte identification code of the Grand Master
Clock.

Clock Class reports the description and code of the Grand Master
Clock Class.

Clock Mode reports the description of the Grand Master Clock
Mode: Two-step or One-step.

Code

Description

0-5, 8-12, 15-51, 53-57, 59-67, 123-132,

171-186, 188-192, 194-215, 233-247, 249-254

Reserved

6

Sync to primary reference

7, 14

Holdover

13

Sync to application-specific reference

52, 58, 187, 193

Degraded

68 to 79, 81-109 (odd values), 11-122,

133-170, 216-232

Alternate PTP profiles

80-110 (even values)

a

a.

Refer to QL table on page 319 for the list of Quality Level values that will be used as the description.

Quality Level (QL-xxx

a

)

248

Default

255

Slave only

Advertising