Esmc generation, Restore synce defaults – EXFO FTB-800 Series for FTB-1 User Manual

Page 240

Advertising
background image

Test Setup - Test Configurator, Timer, and System

230

FTB-700G/800 Series

SyncE

Pass/Fail Verdict check box when selected (default) enables the use
of the pass/fail verdict. The global pass/fail verdict is based on the
following criteria: ESMC Rate Threshold (when enabled), QL
Mismatch Monitoring
(when enabled), ESMC Loss, or Link Down.

ESMC Rate Threshold check box when selected (default) enables the
ESMC rate threshold monitoring which will declare a Fail verdict when
the ESMC frame rate is outside the range of 0.8 to 10.2 frames/s.

ESMC Generation

Generated QL

The Generated QL check box when selected (default) enables the
generation of the selected QL message.

The Generated QL field allows the selection of the QL message that
will be generated. See page 321 for the list of QL message (default is
QL-EEC2/ST3).

Note: For 1GE Electrical interface using Local Clock set to Slave, the Generated

QL is not configurable and is set to QL-DNU/DUS with its check box
selected.

QL Rate (frame/s) defines the frame rate at which the ESMC transmit
the QL message value: 1 (default), 5, or 10 frames per second. For 1GE
Electrical interface using Local Clock set to Slave, the QL Rate is not
configurable and is set to 1 frame/s.

Restore SyncE Defaults

Reverts the SyncE test application to its default factory settings.

Advertising