Test Results

360

FTB-700G/800 Series

Summary (RFC 2544)

Throughput, Back-to-Back, Frame Loss, and
Latency Subtests

Throughput, Back-to-Back, Frame Loss, and Latency

For each subtest, its status (-- (Idle), In Progress, Completed, or
Aborted - (reason)) and duration are displayed.

TX Frames

1

and RX Frames

1

display the transmitted and received

frame counts of the subtest in progress. For Dual Test Set, frame
counts are available for both directions: from local to remote (L->R)
and remote to local (R->L).

Trial #

1

displays the current trial iteration of the subtest in progress

when applicable.

Val. #

1

displays the current validation iteration of the subtest in

progress when applicable.

Step

1

displays the current step of the subtest in progress when

applicable.

Displayed Results: Select the displayed result mode: Current,
Minimum (default), Maximum, or Average.

Throughput/Back-to-Back/Frame Loss/Latency table.

Each frame size used for the test is displayed with its subtest statistics.
Statistics values are presented according with the Displayed Results
setting.

“--” indicates that the result is not available because the test has not
run yet. While testing, one of the following messages is displayed for
each frame size: Initializing, Learning, Testing, Waiting, Not
measurable
, Aborted, Link is Down, or MAC not resolved.

Dir. (Direction), available with Dual Test Set, indicates results from
local to remote (L->R) and remote to local (R->L).

1. Only displayed once the test is started.