EXFO FTB-800 Series for FTB-1 User Manual

Page 293

Advertising
background image

Test Results

NetBlazer

283

Alarms/Errors

ERDI-PSD (Enhanced RDI - Path Server Defect) - SONET
ERDI-SD (Enhanced RDI - Server Defect) - SDH

RX: Bits 5, 6 and 7 of the G1 byte contain the “101” pattern in five
consecutive frames.

TX: Generates a “101” pattern for bits 5, 6 and 7 of the G1 byte.

Errors

B3 (BIP-8, Bit-Interleave Parity - 8 bits)

RX: Indicates a high order path parity error by performing an
even-parity check over all bits of the previous SPE (SONET) / VC-N
(SDH).

REI-P (Remote Error Indicator - Path) - SONET
HP-REI (HP - Remote Error Indicator) - SDH

RX: Bits 1 through 4 of the G1 byte contain one pattern from the
following binary range: “0001” through “1000” (1 to 8) (located in every
STS-1/STM-1 of an STS-n/STM-n signal.

Advertising