Test Functions

392

FTB-700G/800 Series

FDL - Bit-Oriented Message

FDL - Bit-Oriented Message

Allows to set and configure the Bit-Oriented Messages (BOM) of the
Extended Super-Frame (ESF).

Note: FDL is only available for DS1 interface with ESF framing. For Dual RX test,

FDL is only available for the DS1 TX/RX port 1.

From the Test menu, tap Functions, FDL, and the Bit-Oriented Message
tab.

Generated Messages

Priority

Codeword: The Bit-Oriented Message codewords are priority
messages sent over the Data-Link. These messages are mostly used for
networking operation and maintenance. A Bit-Oriented Message
consists of 8 consecutive ones followed by a byte starting and ending
by zeros.

Injects generates the selected codeword priority message.

Command/Response

Codeword

Pattern

RAI

00000000 11111111

Loopback Retention and Acknowledge 00101010 11111111
RAI-CI

00111110 11111111