EXFO FTB-800 Series for FTB-1 User Manual

Page 264

Advertising
background image

Test Results

254

FTB-700G/800 Series

Alarms/Errors

Errors

FAS (Frame Alignment Signal) is only available with PCM30 CRC-4 or
PCM31 CRC-4 framing.

RX: Bits 2 to 8 of the frame containing the FAS differ from 0011011.

CRC-4 (Cyclical Redundancy Check)

RX: One or more bit errors are detected in a block of data through
cyclical redundancy check.

E-Bit (CRC-4 Error Signal) is only available with PCM30 CRC-4 or
PCM31 CRC-4 framing.

RX: Bit 1 of sub-multiframe (SMF) II in frame 13 and/or 15 is set to 0
indicating a sub-multiframe error.

E2

Alarms

Note: Only AIS is available when the framing is set to Unframed.

AIS (Alarm Indication Signal)

RX: An unframed all-ones signal is received.

LOF (Loss Of Frame)

RX: Four consecutive incorrect frame alignment signals is received.

RAI (Remote Alarm Indication)

RX: Bit 11 of a framed E2 is set to “1”.

Errors

FAS (Frame Alignment Signal)

RX: Bits 1 to 10 of the first frame differ from 1111010000.