EXFO FTB-800 Series for FTB-1 User Manual

Page 216

Advertising
background image

Test Setup - Test Configurator, Timer, and System

206

FTB-700G/800 Series

Signal - Signal Configuration (DSn/PDH)

Note: Bit 8 is the Least-Significant Bit (LSB) and bit 1 is the Most-Significant Bit

(MSB).

Payload Content and Set All

Payload Content allows the selection of the payload content that will
be applied to all TX timeslots when tapping the Set All button: Pattern,
Idle, or Tone.

TX

Select the payload content by tapping once or several times on each
timeslot until the desired content appears: Pattern (default), Idle, or
Tone.

Note: For Pattern, the pattern that will be used is the one selected from Pattern on

page 101.

ZCS

Description

Available with

None

a

a.

Default value.

No Zero Code Suppression

DS0 and E0

Jammed Bit 8 Every 8th (LSB) bit is forced to 1.

DS0 and E0

GTE

Bit 8 of an all zero channel byte is

replaced by 1, except in signaling

frames where bit 7 is forced to 1.

DS0

Bell

Bit 7 of an all zero channel byte is

replaced by 1.

DS0

Advertising
This manual is related to the following products: