Test Setup - Test Configurator, Timer, and System
200
FTB-700G/800 Series
Signal (Transport)
Line Coding
RX Termination
Power indicates the received signal lever in dBdsx for DSn or dBm for
PDH and SONET/SDH.
Amplitude indicates the received signal amplitude as well as its MIN,
and MAX received values.
Signal
Line Coding
DS1
AMI and B8ZS
a
a.
Default value.
DS3
B3ZS
E1
AMI and HDB3
a
E3
HDB3
E4
CMI
STS-1e/STM-0e B3ZS
STS-3e/STM-1e CMI
Signal
Termination
DS1/E1
Term
a
, Mon, and Bridge.
a.
Default value.
DS3/E3/E4
STS-1e/STM-0e
STS-3e/STM-1e
Term
a
, and Mon
Advertising