Test Setup - Test Configurator, Timer, and System

154

FTB-700G/800 Series

MAC/IP/UDP

VLAN

Note: VLAN is only available when the VLAN Tag is enabled; refer to Modify

Frame Structure on page 152.

For each VLAN tag enabled, C-VLAN / S-VLAN / E-VLAN, the following
parameters are configurable.

VLAN ID: Enter the VLAN ID. Choices are 0 through 4095; refer to VLAN
ID and Priority
on page 575 for more infor
mation.

Priority: Select the VLAN user priority. Choices are 0 (default) to 7.
Refer to VLAN ID and Priority on page 575 for more information.

Type: Allows the selection of the VLAN Ethernet Type. Choices are
8100 (default for C-VLAN), 88A8 (default for S-VLAN), 9100 (default for
E-VLAN), 9200, and 9300.

Drop Eligible:, when set to Yes (DEI = 1), the transmitted frames will
be dropped first on receipt when congestion occurs under test. Drop
Eligible is not available when VLAN type is 8100. This parameter is set
to No by default.