Test Setup - Test Configurator, Timer, and System

NetBlazer

113

Clock

Line Coding, available with DS1 and E1, allows the selection of the
interface line coding.

For DS1: AMI and B8ZS (default).

For E1: AMI and HDB3 (default).

Framing, available with DS1 and E1, allows the selection of the
interface framing.

For DS1: SF, SLC-96, and ESF (default).

For E1: PCM30 (default), PCM30 CRC-4, PCM31, and PCM31 CRC-4.

Frequency (MHz) displays the frequency of the generated clock signal on
the port.

Clock Out indicates that a clock is generated on the port (green) or not
(red).