Answer mode – EXFO FTB-800 Series for FTB-1 User Manual

Page 155

Advertising
background image

Test Setup - Test Configurator, Timer, and System

NetBlazer

145

ISDN PRI - Call Management

Call

Type selects the service type: 3.1 kHz, Speech, or Data (default).

Rate is only configurable for Data type: 56K or 64K (default). The
rate is set 64K for 3.1 kHz and Speech types as well as for
Euro Q.SIG switch type.

Network

Transit Net Code (Transit Network Code) selects a specific
network on which the call is placed and is only applicable in TE -
Emulation Mode. The range is from 0 to 9999. By default this field
is blank meaning that no Transit Network Selection code is
transmitted. Not supported with Euro Q.SIG switch type.

Operator Sys Access (Operator System Access) determines
whether or not an operator is used: Disabled (default), Principal,
and Alternate. Only applies to National ISDN switch type, Speech
and 3.1 kHz call type, and in TE - Emulation Mode.

Answer Mode

Allows the selection of the call answering mode.

Auto-Answer (default) answers all incoming calls automatically.

Auto-Reject rejects all incoming calls automatically.

Prompt: asks to answer or reject a call. A call answered or rejected is
removed from the table in the Answer Prompt window. All incoming
calls are listed in the received order.

Calls can be answered or rejected individually (Answer/Reject) or
collectively (Answer All/Reject All).

The Close button is available once all calls are answered or rejected.