Labels

Labels

From the Test menu, tap Setup, Test Configurator, the protocol block, and
on the Labels tab.

Note: Selecting a Label byte to be generated will automatically update the

corresponding OH byte. Refer to OH - SONET/SDH on page 422 for more
information.

Labels

STS/AU Path (C2): The C2 byte is allocated to indicate the content of
the STS SPE / VC, including the status of the mapped payloads.

Generated: Select the C2 byte from the list. Selecting a C2 byte value
will automatically update the OH C2 selection and vice versa. Refer to
C2 on page 429 for more information.

PLM-P/UNEQ-P / HP-PLM/HP-UNEQ: Enables the Payload Mismatch
and STS/AU UNEQ monitoring. This setting is coupled with the
configuration of Traces - SONET/SDH on page 375.

Expected: Select the expected C2 byte from the list. Refer to C2 on
page 429 for more information.

VT/TU Path (V5): The V5 byte is allocated to indicate the content of the
VT/TU path, including the status of the mapped payloads.

Generated: Select the V5 byte from the list. Selecting a V5 byte value
will automatically update the OH V5 selection and vice versa. Refer to
V5 on page 432 for more information.

PLM-V/UNEQ-V / LP-PLM/LP-UNEQ: Enables the Payload Mismatch
and VT/TU UNEQ monitoring. This setting is coupled with the
configuration on the Labels on page 306.

Expected: Select the expected V5 byte from the list. Refer to V5 on
page 432 for more information.