Opux – EXFO FTB-800 Series for FTB-1 User Manual

Page 279

Advertising
background image

Test Results

NetBlazer

269

Alarms/Errors

OPUx

Note: OPUx is displayed under ODUx alarms/errors group.

Alarms

AIS (Alarm Indication Signal) .

RX: A PRBS11 pattern is received indicating a failure of the client
signal.

TX: Generates a PRBS11 pattern.

CSF (Client Signal Fail) .

RX: Bit 1 of the OPUk PSI[2] byte is set to “1” indicating a failure of the
client signal mapped into the OPUk of the OTN signal.

TX: Sets the bit 1 of the OPUk PSI[2] byte to “1”.

PLM (Payload Mismatch) is available when OPU-PLM check box is
selected.

RX: The Payload Structure Identifier (PSI) field do not match the
expected PT for at least 3 consecutive frames.