Bit error, Service disruption – EXFO FTB-800 Series for FTB-1 User Manual

Page 113

Advertising
background image

Test Setup - Test Configurator, Timer, and System

NetBlazer

103

BERT

For Multi-Pattern, see Multi-Pattern Configuration on page 106.

When User Pattern is selected, enter the payload pattern hexadecimal
value.

Invert check box, when selected (cleared by default), inverts the test
pattern meaning that every 0 will be changed for 1 and every 1 for 0.
For example, the pattern 1100 will be sent as 0011. Not available when
pattern is Multi-Pattern.

Bit Error

Pass/Fail Verdict allows to enable bit-error-rate pass/fail verdict by
selecting either Bit Error Count or Bit Error Rate. The default value is
Disabled.

BER Threshold allows to enter the threshold Count or Rate value that
will be used to declare the pass/fail verdict. The BER Threshold
applies to individual pattern for Multi-Pattern.

For Count, enter the maximum bit error count allowed before
declaring a fail verdict: 0 (default) to 999999.

For Rate, enter the maximum bit error rate allowed before declaring a
fail verdict: 1.0E-14 to 1.9E-01. The default value is 1.0E-12.

Service Disruption

Note: Service Disruption is not available for Multi-Pattern.

The Service Disruption Time (SDT) corresponds to the duration associated
to a defect that occurred in the network. For example a disruption that
occurs during a network switching from the active channels to the backup
channels or vice versa.

Note: The service disruption measurements are cleared when changing the

criteria.