Test Setup - Test Configurator, Timer, and System

NetBlazer

179

RFC 2544 - Subtests

Thresholds Button

Note: For Dual Test Set, thresholds are configurable for Local to Remote and

Remote to Local directions at the exception of Round-Trip Latency
Threshold for which the value is unique.

Throughput Threshold allows to set the threshold

1

value used to

declare a pass/fail verdict and it applies to all frame sizes when
applicable. The range is as follows:

Back-to-Back Threshold allows to set the threshold

1

value in

percentage of frames per burst to declare a pass/fail verdict. The range
is from 0.0 to 100.0% (default) and it applies to all frames sizes when
applicable.

Frame Loss Threshold (%) allows to set the threshold

2

value of frame

loss. The range is from 0.000 to 100.000 (default is 0.100) and it
applies to all frame sizes when applicable.

1. The verdict is PASS when the received/measured value is greater or equal to the threshold value.

Interface

Speed

Max. Rate

%

Mbit/s

Gbit/s

10 Mbit/s

0.000 to 100.000

a

a.

Defalut value.

0.000 - 10.000

a

Not Applicable

100 Mbit/s

0.000 to 100.000

a

0.000 - 100.000

a

Not Applicable

1000 Mbit/s

0.000 to 100.000

a

0.000 - 1000.000

a

0.000 - 1.000

a

10G LAN

0.000 to 100.000

a

0.000 - 10000.000

a

0.000 - 10.000

a

10G WAN

b

b.

The maximum value for 10G WAN may be lower depending on the frame size. The

maximum value will be adjusted for each frame size.

0.000 to 92.8571

a

0.000 - 9230.769

a

0.000 - 9.230

a

2. The verdict is PASS when the received/measured value is lower or equal to the threshold value.