Physical interface - electrical – EXFO FTB-800 Series for FTB-1 User Manual

Page 209

Advertising
background image

Test Setup - Test Configurator, Timer, and System

NetBlazer

199

Signal (Transport)

Physical Interface - Electrical

Note: The following settings are available with electrical signal and their

availability depend on the signal itself and its mapping. For optical
interface, see Physical Interface - Optical
on page 198.

LBO (Line Build Out): The LBO allows to meet the interface
requirements over the full range of cable lengths.

Signal

LBO

DS1

Preamplification values: DSX-1 (0-133 ft)

a

,

DSX-1 (133-266 ft), DSX-1 (266-399 ft),
DSX-1 (399-533 ft), DSX-1 (533-655 ft),

Cable simulation (CSU Emulation mode) values:
CSU (0.0 dB), CSU (-7.5 dB), CSU (-15.0 dB),
CSU (-22.5 dB).

a.

Default value

DS3

0 to 225 ft range

a

, 225 to 450 ft range, and Cable

Simulation 900 ft.

E1/E3/E4

Not available

STS-1e/STM-0e 0 to 225 ft range

a

, 225 to 450 ft range, and Cable

Simulation 900 ft).

STS-3e/STM-1e 0 to 225 ft range.