Test Setup - Test Configurator, Timer, and System

NetBlazer

191

Services - Profile

Services - Profile

The EtherSAM test application supports the configuration of up to 10
different services individually. All parameters are configurable per service.

From the Test menu, tap Setup, Test Configurator, tap on the services
block, and on the Profile tab.

Service Selection and Activation

Select the service to be configured by either using the left/right arrow or by
tapping over the service numbers area then tapping on a specific service
number. An orange background indicates the selected service while a
green background indicates the services that are enabled.

Service associates a name to the selected service number. Up to 16
characters are allowed. Default service names are Service 1 to
Service 10.

Enable check box when selected (cleared by default) enables the
selected service. However, the service will be generated only when the
test is started. For Dual Test Set, services can only be enabled once the
connection with the remote unit is established.

When the Service Performance Test is enabled, up to 10 services can
be enabled one after the other, as long as the Total TX Rate
(bandwidth) is not reached (Committed). For example, if the first
service is using the full bandwidth available, then no other service can
be enabled. If the first enabled service uses half bandwidth, then at
least another service can be enabled using up to half bandwidth. Thus,
to enable a second service, first set the CIR value within the non-used
bandwidth (Available), then enable it.

When the Service Performance Test is disabled, up to 10 services can
be enabled one after the other; the total TX rate is not limited.

Advertising