Rx frequency – EXFO FTB-800 Series for FTB-1 User Manual

Page 212

Advertising
background image

Test Setup - Test Configurator, Timer, and System

202

FTB-700G/800 Series

Signal (Transport)

Step Size (ppm) allows to set the increment/decrement value (from
0.1 to either 50 or 120 depending on the test configuration) that will be
used when changing the frequency offset with the “+” or “-” button.

RX Frequency

Frequency (GHz) indicates the frequency of the input signal.

Offset (ppm) indicates the frequency offset between the standard rate
specification and the rate at the input signal.

Note: For both Frequency and Offset the following background colors are used.

Max. Negative Offset (ppm) indicates the maximum negative
frequency offset between the standard rate specification and the rate
from the received signal.

OTU1e

± 120 ppm

11049107143 bit/s

OTU2e 11095727848

bit/s

OTU1f 11270089286

bit/s

OTU2f 11317642405

bit/s

a.

The frequency offset range is guaranteed for a source signal at 0 ppm. In the event

that the source signal already has an offset, then the output signal may exhibit an

offset larger than the range specified.

Background color

Description

Green

The frequency is in range.

Red

The frequency is out-of-range. LOC is also

displayed.

Gray

Pending state.

Interface

Frequency Offset

a

Nominal Frequency

Advertising
This manual is related to the following products: