Test Functions

428

FTB-700G/800 Series

OH - SONET/SDH

For OC-192: Either the M1 byte located in the STS-1 #7, or the
combination of the M0 and M1 bytes indicates BIP violations (refer
to REI-L Computation Method on page 215).

For M1 Only computation method:

For M0 and M1 computation method:

Z2: Growth. Available with OC-3, OC-12, and OC-48 signal, this byte is
located in STS-1 #1 up to STS-1 #48 except for timeslots used by M0
and M1.

Undefined “--” for all other timeslots not covered by M0, M1, and Z2.

M1

Indicates

0000 0000

0 BIP violation

0000 0001

1 BIP violation

:

:

1111 1111

255 BIP violations

M0

Located in STS-1 #4

M1

Located in STS-1 #7

Indicates

0000 0000

0000 0000

0 BIP violation

0000 0000

0000 0001

1 BIP violation

:

:

:

0000 0110

0000 0000

1536 BIP violations

0000 0110 to

1111 1111

0000 0001 to

1111 1111

0 BIP violation