Test Setup - Test Configurator, Timer, and System

188

FTB-700G/800 Series

Services - Global

Services - Global

From the Test menu, tap Setup, Test Configurator, tap on the services
block, the Global tab, and on the General button.

General Button

The following parameters are displayed and configurable per service.

Check boxes:

The first check box (top-left) allows to sequentially enable
service(s) within the limit of the link capacity when the Service
Performance Test
is enabled or enable all services when the
Service Performance Test is disabled.

The check boxes next to the service numbers allow to enable each
service individually.

When the Service Performance Test is enabled, up to 10 services
can be enabled one after the other, as long as the Total TX Rate
(bandwidth) is not reached (Committed). For example, if the first
service is using the full bandwidth available, then no other service
can be enabled. If the first enabled service uses half bandwidth,
then at least another service can be enabled using up to half
bandwidth. Thus, to enable a second service, first set the CIR value
within the non-used bandwidth (Available), then enable it.

When the Service Performance Test is disabled, up to 10 services
can be enabled one after the other; the total TX rate is not limited.

Service Name

1

indicates the name of each service. Tap on the Service

Name button to modify the name of each service.

Direction, available with Dual Test Set, indicates results from local to
remote (L -> R) and remote to local (R -> L).

1. See Services - Profile on page 191 for more information.