Test Functions

452

FTB-700G/800 Series

Pointer Adjustment

RX Pointer Adjustment

Pointer Value

For STS/AU: Displays the value for the pointer, H1 and H2, indicating the
offset in bytes between the pointer and the first byte of the STS-n
(SONET) or AU-n (SDH).

For VT/TU: Displays the value of the pointer, V1 and V2, indicating the
offset in bytes between the pointer and the first byte of the VTn
(SONET) or TU-n (SDH) of the high order path. However, TU-3
considered a low order path, uses the H1, H2, H3 bytes for its location.

Cumulative Offset indicates the difference between the pointer
increment and the pointer decrement. A pointer jump will reset this
value to 0.

Ptr. Incr. (Pointer Increment) gives statistics on positive pointer
adjustment detected.

Ptr. Decr. (Pointer Decrement) gives statistics on negative pointer
adjustment detected.

Periodic pointer adjustment 26-1 pattern

Basic sequence

a

Duration 60 sec

Basic sequence

a

Duration = 30 sec

Periodic 26-1 with Add

Add sequence

Duration = 30 sec

Periodic 26-1 with Cancel Cancel

sequence

Duration = 30 sec

a.

The basic sequence corresponds to the pointer event pattern defined in the standard without any Add or

extra Cancel event.

b.

Only available when the Periodic check box is selected.

Pointer Sequence Pattern

Initialization