Ethersam - ramp, Dynamic ramp, Step time – EXFO FTB-800 Series for FTB-1 User Manual

Page 134: Ramp duration, Add step

Advertising
background image

Test Setup - Test Configurator, Timer, and System

124

FTB-700G/800 Series

EtherSAM - Ramp

EtherSAM - Ramp

Note: The Ramp tab is only available for configuration when the Ramp Test

check box is selected (see page 120).

From the Test menu, tap Setup, Test Configurator, tap on the test block,
and on the Ramp tab.

Note: The ramp configuration parameters are defined globally for all services but

the presence of CIR+EIR, and Traffic Policing steps are as per each service
configuration. CIR, CIR+EIR, and Traffic Policing steps are part of the step
list as soon as they are enabled for at least one service even if that service is
not enabled.

Dynamic Ramp

The graphic displays the percentage of each CIR level step in time.

Step Time

The step time is the test duration for each ramp step: 5 (default) to
60 seconds.

Ramp Duration

The ramp duration indicates the total time required to perform all the ramp
steps for each service.

Add Step

Allows to add a new ramp step. Enter the CIR percentage from 1 to 99.
A maximum of 7 pre CIR steps can be added in the ramp configuration.