Test Results

366

FTB-700G/800 Series

Summary (SyncE)

Summary (SyncE)

From the Test menu, tap Results, and the Summary tab.

Test Status displays the current status of the SyncE test. The global test
pass/fail verdict is displayed next to the Test Status when enabled (see
Pass/Fail Verdict on page 230).

Start Time indicates the time the test was started.

ESMC

Indicates the current (meter and value), average, minimum, and
maximum ESMC frame rate (including information and event frames)
received in frame/s. A fail verdict is also displayed beside the minimum
and/or maximum values when the ESMC frame rate is outside the range
while the Pass/Fail Verdict is enabled.

ESMC RX Rate meter displays the current ESMC frame rate (including
information and event frames) in frame/s averaged over the last 11 frames
received. The pass/fail verdict is also displayed when enabled.

Note: When the Pass/Fail Verdict and ESMC Rate Threshold check boxes are

selected (see page 230), the green region is delimited from 0.8 to 10.2
frames/s corresponding to a PASS verdict. The red regions above and
beyond the threshold correspond to a FAIL verdict. There is neither green
nor red region when the Pass/Fail verdict is disabled.

Test Status

Description

--

The test is not running or results are not available.

In Progress The test is running.

Completed The test is completed, stopped at the planned time, or

manually stopped when there is no set timer.

Aborted

The test is interrupted; stopped before the set timer.