Pass/fail verdict, Thresholds – EXFO FTB-800 Series for FTB-1 User Manual

Page 192

Advertising
background image

Test Setup - Test Configurator, Timer, and System

182

FTB-700G/800 Series

S-OAM

Pass/Fail Verdict

Pass/Fail Verdict check box when selected (default) enables the use of the
pass/fail verdict. A global fail verdict is declared when any of the following
condition is met: Link Down alarm, Loss Continuity alarm, or any fail
verdict for Frame Delay, Frame Loss, Synthetic Loss, Frame Delay
Failure
, Frame Loss Failure, Synthetic Loss Failure, Loopback Failure,
or Test Failure.

Thresholds

Available with Y.1731 and MEF S-OAM Modes when Pass/Fail verdict is
enabled.

Frame Delay Threshold (ms) allows to set the threshold

1

value of

frame delay: 0.001 to 8000 ms (default is 50 ms).

Frame Loss Threshold (%) allows to set the threshold

1

value of frame

loss: 0.001 to 100 % (default is 10 %).

Synthetic Loss Threshold (%) allows to set the threshold

1

value of

Synthetic Loss: 0.001 to 100 % (default is 10 %).

1. The verdict is PASS when the measured value is lower or equal to the threshold value.