Fdl - performance report message, Generated messages – EXFO FTB-800 Series for FTB-1 User Manual

Page 408

Advertising
background image

Test Functions

398

FTB-700G/800 Series

FDL - Performance Report Message

FDL - Performance Report Message

Note: FDL PRM is only available for DS1 interface with ESF framing. For Dual RX

test, FDL is only available for the DS1 TX/RX port 1. For NI/CSU Emulation,
only available in the RX direction.

From the Test menu, tap Results, tap the FDL, and
Performance Report Message tab.

Generated Messages

Circuit allows the selection of the circuit type: CI to Network (default)
or Network to CI.

ANSI T1-403 check box when selected allows the generation of a
compliant ANSI T1.403 PRM Message.

Injection

Single sends the selected PRM Message(s) manually.

Continuous generates the selected PRM Message(s) continuously.

Event Count indicates the number of PRM messages sent.

PRM Bit Events allows the activation of the following PRM bit events.
All PRM bit events are disabled by default.

G1: CRC = 1

G2: 1 < CRC  5

G3: 5 < CRC 10

G4: 10 < CRC  100

G5: 100 < CRC 319

G6: CRC  320

SE: Severely errored framing  1

FE: Frame sync. bit error  1

LV: Line code violation event  1

LB: Payload loopback activated

SL: Slip  1

R Bit (Reserved - Default value is 0)

U1: Bit

U2: Bit

Advertising