Test Functions

NetBlazer

435

OH - SONET/SDH

Z7 /K4 : Extended signal label

Default all OH

Returns all TX overhead bytes to their factory default values.

Bits

Description

Z7 (SONET)

K4 (SDH)

1

Extended signal label. Bits 12 to 19 of the 32 bit frame

multiframe (see Z7/K4 Structure on page 433) contain the

extended signal label.

2

Virtual concatenation. Bits 1 to 5 of the 32 bit frame multiframe

(see Z7/K4 Structure on page 433) contain the LO virtual

concatenation frame count while bits 6 to 11 contain the LO

virtual concatenation sequence indicator.

3 - 4 unassigned and reserved for APS signaling for protection at the

lower order path level.

5 - 7 These bits in combination

with bit 8 of V5 are allocated

for RDI -V/ERDI-V signal

Optional use.

8

unassigned and reserved for a lower order path data link.