Test Setup - Test Applications

NetBlazer

53

RFC 2544

RFC 2544

RFC 2544 allows Ethernet Throughput, Back-to-Back, Frame Loss, and
Latency performance testing in accordance with RFC 2544 specifications.

The RFC 2544 test has to be executed in conjunction with a remote
module. The remote module can be either in loopback configuration for
unidirectional testing or in RFC 2544 Dual Test Set mode for bidirectional
testing.

The Dual Test Set test allows bi-directional test between two compatible
modules providing independent results for each test direction. The results
from local-to-remote and remote-to-local are available on the local testing
unit.

Typical RFC 2544 testapplications:

Supported Interfaces/Rates: 10M to 10G LAN/WAN.

Network

under test

Testing Unit

Loopback Unit

FTB-700G/800 Series

FTB-700G/800 Series

Network

under test

Testing Unit

Remote Unit

FTB-700G/800 Series

FTB-700G/800 Series