Test Setup - Test Configurator, Timer, and System

NetBlazer

129

FTFL/PT

Note: The Code field is automatically updated when the Payload Type is

changed and vice versa.

OPU-PLM, when selected, enables the OPU-PLM alarm analysis.

ODU Multiplex with ODTUjk

20

0010

0000

ODU Multiplex with ODTUk.ts/ODTUjk

21

0010

0001

Not Available

b

55

0101

0101

Reserved Codes for Proprietary Use

c

80

1000

0000

NULL Test Signal mapping

FD

1111

1101

PRBS Test Signal mapping

FE

1111

1110

a.

Selecting Reserved for International Standardization will use the hexadecimal code 00 but, all codes

not listed in the previous table at the exception of those covered in notes b and c are reserved for future

standardization.

b.

Selecting Not Available will use the hexadecimal code 55 but, 66 and FF are also Not Available payload

types.

c.

Selecting Reserved Proprietary will use the hexadecimal code 80 but, all codes from 80 to 8F are

reserved proprietary payload types.

Payload type

Hex Code

MSB

1234

LSB

5678