Tx pointer adjustment - sequence button – EXFO FTB-800 Series for FTB-1 User Manual

Page 453

Advertising
background image

Test Functions

NetBlazer

443

Pointer Adjustment

TX Pointer Adjustment - Sequence Button

Note: The pointer sequence is only supported on one test layer; either on VT/TU

layer or on STS/AU when the test doesn’t contain VT/TU mapping. The field
next to the
Sequence operation mode button indicates the path level used
for the sequence pointer adjustment.

Sequence: T.105-03/GR-253 allows the selection of the pointer
sequence pattern based on the T.105-03/GR-253 standard.

Pointer Sequence Pattern

Available with

Single pointers of opposite polarity

AU-x, TU-3, TU-11, TU-12

Regular pointers plus one double pointer

AU-x, TU-3, TU-11, TU-12

Regular pointers with one missing pointer AU-x, TU-3, TU-11, TU-12
Double pointers of opposite polarity

AU-x, TU-3, TU-11, TU-12

Single pointer adjustment

STS-x, VT1.5, VT2,

AU-x, TU-3, TU-11, TU-12

Burst pointer adjustment

STS-x, VT1.5, VT2,

AU-x, TU-3, TU-11, TU-12

Phase transient

STS-x, VT1.5, VT2,

AU-x, TU-3, TU-11, TU-12

Periodic pointer adjustment 87-3 pattern

STS-x, AU-x, TU-3

Periodic 87-3 with Add

STS-x, AU-x, TU-3

Periodic 87-3 with Cancel

STS-x, AU-x, TU-3

Periodic pointer adjustment continuous

STS-x, VT1.5, VT2,

AU-x, TU-3, TU-11, TU-12

Periodic pointer adjustment continuous

with Add

STS-x, VT1.5, VT2,

AU-x, TU-3, TU-11, TU-12

Periodic pointer adjustment continuous

with Cancel

STS-x, VT1.5, VT2,

AU-x, TU-3, TU-11, TU-12