Synchronization interface, Specifications, 517 synchronization interface – EXFO FTB-800 Series for FTB-1 User Manual

Page 527: Synchronization interfaces, Netblazer

Advertising
background image

Specifications

NetBlazer

517

Synchronization Interface

Synchronization Interface

SYNCHRONIZATION INTERFACES

External Clock DS1/1.5M

External Clock E1/2M

External Clock E1/2M

Trigger 2 MHz

Tx pulse amplitude (V)

2.4 to 3.6

3.0

2.37

0.75 to 1.5

Tx pulse mask

GR-499 Figure 9.5

G.703 Figure 15

G.703 Figure 15

G.703 Figure 20

Tx LBO preamplification

Typical power dBdsx

+0.6 dBdsx (0–133 ft)

+1.2 dBdsx (133–266 ft)
+1.8 dBdsx (266–399 ft)
+2.4 dBdsx (399–533 ft)
+3.0 dBdsx (533–655 ft)

Rx level sensitivity

TERM:

)6 dB (cable loss only)

(at 772 kHz for T1)

DSX-MON:

)26 dB (20 dB resistive

loss + cable loss

) 6 dB)

Bridge:

)6 dB (cable loss only)

TERM:

)6 dB (cable loss only)

MON:

)26 dB (20 dB resistive loss

+ cable loss

) 6 dB)

Bridge:

)6 dB (cable loss only)

TERM:

)6 dB (cable loss only)

MON:

)26 dB (resistive loss

+ cable loss

) 6 dB)

Bridge:

)6 dB (cable loss only)

)6 dB (cable loss only)

Transmission bit rate

1.544 Mbit/s ± 4.6 ppm

2.048 Mbit/s ± 4.6 ppm

2.048 Mbit/s ± 4.6 ppm

Reception bit rate

1.544 Mbit/s ± 50 ppm

2.048 Mbit/s ± 50 ppm

2.048 Mbit/s ± 50 ppm

Intrinsic jitter (Tx)

ANSI T1.403 section 6.3

GR-499 section 7.3

G.823 section 6.1

G.823 section 6.1

G.703 table 11

Input jitter tolerance

AT&T PUB 62411

GR-499 section 7.3

G.823 section 7.2

G.813

G.823 section 7.2

G.813

G.823 section 7.1
G.751 section 3.3

Line coding

AMI and B8ZS

AMI and HDB3

AMI and HDB3

Input impedance (resistive termination)

75 ohms ± 5 %, unbalanced

75 ohms ± 5 %, unbalanced

75 ohms ± 5 %, unbalanced

75 ohms ± 5 %, unbalanced

Connector type

BNC

a

BNC

a

BNC

BNC

Note

a. Adaptation cable required for BANTAM.