Test Results

246

FTB-700G/800 Series

Alarms/Errors

Alarms/Errors

From the Test menu, tap Results, and the Alarms/Errors tab. Depending
on the test structure, the Alarms/Errors page may be split in different tabs
such as OTN, and Ethernet; tap on the desired tab when required.

Alarms/errors blocks containing the magnifier (+) icon in its title, opens a
zoomed view giving more details like errors in seconds, count, and rate.

When there is not enough room on the page to display the error in
seconds, count, and rate, the error is displayed in Seconds per default. To
select another unit, tap on the unit’s button and select either Seconds
(default), Count, or Rate.

The following table lists the availability of alarms/errors per layer for
TX and RX.

Layer

Alarms/Errors

Page

TX/RX

RX only

BER

Pattern Loss

No Traffic

249

Bit Error, Pattern Error

Mismatch ‘0’, Mismatch ‘1’,
Frame Loss, Out-of-Seq.

CLOCK

-

LOC, LOPPS-L, LOPPS-R

250

DS1

AIS. OOF, RAI

-

251

CRC-6, Framing Bit

-

DS3

AIS, Idle, OOF, RDI

-

252

CP-BIT, FEBE, F-Bit, P-Bit

-

E1

AIS, LOF, RAI, LOMF, RAI MF, TS16 AIS

-

253

FAS

CRC-4, E-Bit

E2
E3
E4

AIS, LOF, RAI

-

254
255
256

FAS

-