stages of post-production and should not be used
unless absolutely necessary.

Frame Rate

Use this tab to set the frame rate for

the timecode used in the project. Frame rates from 24
through 30 are supported.

NOTE

To access 30-drop-frame (usually grayed out as this is
not a common frame rate), hold down the SHIFT key on
the PS/2 keyboard while left-clicking this tab.

SMPTE/TIMECODE OFFSET

This parameter

determines the amount of offset from incoming and
outgoing timecode. Values can be entered by using
the PS/2 keyboard.

FRAME RESOLVE

Use this setting to resolve

timecode to the frames received through the video
sync input.

LCD Clock Settings Screen

This LCD screen reflects the parameters of the

Clock

Settings

tab found on the

Settings

screen of the VGA.

From the

MAIN DISPLAY MODE

section, press

SETTINGS/ PREFS

, and use

NEXT PAGE

(or

PREV

PAGE

) soft key to scroll to the

CLOCK

screen.

SELECT Fs

This soft knob selects the mixer sample

rate.

SELECT SOURCE

This soft knob opens a menu

where a clock source can be chosen.

SELECT PRI CLK

This soft key sets the source you

have selected as the Primary clock master.

SELECT SEC CLK

This soft key sets the source you

have selected as the Secondary clock master.

SET TO DEFAULT

Pressing this soft key sets the

selected control in question to the factory default
value.

AUTO RETRY

Knowing that the SX-1 can switch

to another clock source if the Primary selection
becomes unstable, this setting determines whether or
not the master clock will be switched back to Pri-
mary if that clock again becomes stable.

MANUAL RETRY

Pressing this soft key causes

the SX-1 to manually search for a valid clock on the
Primary selection’s port.