Assigning OCU-DP Data Ports

Use the OCU-DP Port Assignments screen to view the status of:

H

All DS0 assignments on the Network interface

H

All DS0 assignments on the DSX-1 interface

You can also use this screen to assign OCU-DP data ports to:

H

Network interface timeslots

H

DSX-1 interface timeslots

NOTES:

You can assign OCU-DP ports to the DSX-1 interface on the 9161 Single
T1 NAM. OCU-DP port assignments on the Dual DSX APM are not
supported.

"

Procedure

1. Follow this menu selection sequence:

Configuration Edit/Display

Cross Connect

OCU-DP Port Assignment

2. The OCU-DP Port Assignments screen appears. Enter one of the following

into the Assign To field:

If you want to assign to . . .

Then enter . . .

Network interface timeslots

Net1 or Net2

DSX-1 interface timeslots on the 9161
Single T1 NAM

DSX01-1

3. Move the cursor to the next editable timeslot (underlined). Use the spacebar

or type in the desired slot and port. Repeat this step until all desired timeslots
are assigned.

4. Select Save to save the assignments, or press ESC to save and return to the

Cross Connect menu.