Paradyne T1 T1 Access Mux 926x User Manual

Page 88

Advertising
background image

Setting Up

5-34

9161-A2-GH30-30

April 1998

Table 5-7.

OCU-DP Options – Slot ss Port p Options (3 of 3)

64KCC Loop OOF Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether an ASCII alarm will be generated when a 64KCC Loop Out of
Frame (OOF) condition is detected.

H

A 64KCC Loop Out of Frame (OOF) Alarm only appears if Port Status is set to
Enable.

Enable – An alarm is generated when a 64KCC Loop Out of Frame condition is
detected on the interface.

Disable – Alarms are not generated for a 64KCC Loop Out of Frame condition.

DDS Network Failure Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether an ASCII alarm will be generated when a DDS Network Failure
code is received from the network.

H

DDS Network Failure Alarm only appears if Port Status is set to Enable.

Enable – An alarm is generated when a DDS Network Failure code is received from the
network.

Disable – Alarms are not generated for a DDS Network Failure.

Loss of Loop Timing Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether an ASCII alarm will be generated when a Loss of Loop Timing
condition is received from the network.

H

Loss of Loop Timing Alarm only appears if Port Status is set to Enable.

Enable – An alarm is generated when a Loss of Loop Timing condition is detected on
the interface.

Disable – Alarms are not generated for a Loss of Loop Timing condition.