Paradyne T1 T1 Access Mux 926x User Manual

Page 105

Advertising
background image

Setting Up

5-51

9161-A2-GH30-30

April 1998

Table 5-9.

System Options (4 of 4)

External Clock Rate (KHz)

Possible Settings: 8, 1544, 2048
Default Setting: 1544

Determines the clock rate when a clock source is configured for an external clock in
kilohertz.

H

External Clock Rate only appears if Primary or Secondary Clock Source is set to
External.

8 – The external clock rate is 8 KHz.

1544 – The external clock rate is 1544 KHz.

2048 – The external clock rate is 2048 KHz.

Primary Clock Failure Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an ASCII alarm message is generated when a Primary Clock Failure
is detected.

Enable – Generates an ASCII alarm message.

Disable – Does not generate an ASCII alarm message.

Secondary Clock Failure Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an ASCII alarm message is generated when a Secondary Clock
Failure is detected.

Enable – Generates an ASCII alarm message.

Disable – Does not generate an ASCII alarm message.