Paradyne T1 T1 Access Mux 926x User Manual

Page 108

Advertising
background image

Setting Up

5-54

9161-A2-GH30-30

April 1998

Table 5-10.

Communication Port Options (3 of 5)

Character Length

Possible Settings: 7, 8
Default Setting: 8

Specifies the number of bits needed to represent one character. The character length
must be set to 8 bits when using the communication port as the network communication
link.

H

Character length defaults to 8 and cannot be changed if Port Use is set to Net Link
and Port Type is set to Asynchronous.

7 – Sets the character length to seven bits.

8 – Sets the character length to eight bits. You must use this setting if using the COM
port as the network communication link.

Parity

Possible Settings: None, Even, Odd
Default Setting: None

Provides a method of checking the accuracy of binary numbers for the COM port.

None – Provides no Parity.

Even – Makes the sum of all 1 bits in the character and its corresponding parity bit
always even.

Odd – Makes the sum of all 1 bits in the character and its corresponding parity bit
always odd.

Stop Bits

Possible Settings: 1, 1.5, 2
Default Setting: 1

Determines the number of stop bits used for the COM port.

1 – Provides one stop bit.

1.5 – Provides one and a half stop bits.

2 – Provides two stop bits.

Ignore Control Leads

Possible Settings: Disable, DTR
Default Setting: Disable

Specifies whether Data Terminal Ready (DTR) is used.

Disable – Treats control leads as standard operation.

DTR – Ignores DTR. This may be necessary when connecting to some PAD (Packet
Assembly and Disassembly) devices.

Advertising