Setting Up

5-22

9161-A2-GH30-30

April 1998

Table 5-3.

Synchronous Data Port Options (6 of 7)

Near-End Performance Statistics

Possible Settings: Disable, Maintain, Send, Both
Default Setting: Disable

Specifies whether the T1 access unit maintains near-end performance statistics and
sends Performance Report Messages (PRMs) for the synchronous data port.

H

Near-End Performance Statistics does not appear if:

– EDL is set to Disable.

– Management Link is set to FDL.

NOTE:

If the local T1 access unit is configured to send near-end performance
statistics, then the remote T1 access unit must be configured to maintain
far-end performance statistics.

Disable – Does not maintain near-end performance statistics or send PRMs.

Maintain – Maintain near-end performance statistics for the port.

Send – Send PRMs over the port’s EDL every second. Each PRM contains the
performance statistics for the previous 4 seconds.

Both – Maintain near-end performance statistics and send PRMs over the port’s EDL.

Far-End Performance Statistics

Possible Settings: Disable, Maintain
Default Setting: Disable

Specifies whether the T1 access unit maintains far-end performance statistics and
sends Performance Report Messages (PRMs) for the synchronous data port.

H

Far-End Performance Statistics does not appear if:

– EDL is set to Disable.

– Management Link is set to FDL.

NOTE:

If the local T1 access unit is configured to maintain far-end performance
statistics, then the remote T1 access unit must be configured to send
near-end performance statistics.

Disable – Does not monitor the port’s EDL for PRMs or maintain far-end performance
statistics.

Maintain – Monitors the port’s EDL for PRMs and maintains far-end performance
statistics.

Out of Frame (OOF) Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Out of Frame (OOF). Specifies whether an alarm is generated when an out-of-frame
condition is detected on the synchronous data port.

H

Out of Frame does not appear if:

– Embedded Data Link is set to Disable.

– Management Link is set to FDL on the Network Interface Options screen (see

Table 5-1).

Enable – Generates an alarm.

Disable – Does not generate an alarm.