Paradyne T1 T1 Access Mux 926x User Manual

Page 197

Advertising
background image

Troubleshooting

9-15

9161-A2-GH30-30

April 1998

Table 9-1.

ASCII Alarm Messages (3 of 5)

Message

Priority

What To Do

What It Indicates

month/day/year
hours:minutes:seconds –
A DDS Network Failure
code has been received at
OCU-DP port in slot

ss

port

p.

A DDS network failure
is being detected on
the specified OCU-DP
port.

Contact the DDS
service provider.

19

month/day/year
hours:minutes:seconds –
Alarm Cleared for a DDS
Network Failure code at
OCU-DP port in slot

ss

port

p.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
An Excessive Error Rate
(EER) has been detected at
the Network 1/ Network 2
Interface.

An Excessive Error
Rate condition is
detected on the
network interface.

Contact network
provider.

12

month/day/year
hours:minutes:seconds –
Alarm Cleared for
Excessive Error Rate
(EER) at the Network
1/Network 2 Interface.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours/minutes/seconds –
An Excessive Error Rate
(EER) has been detected at
synchronous data port in
slot

ss port p.

An excessive error
rate occurred on the
synchronous data port
for the identified slot
and port.

There is a network
problem with the
fractional portion of
the link carrying this
port’s data. Contact
network provider.

14

month/day/year
hours:minutes:seconds –
Alarm Cleared for
Excessive Error Rate
(EER) at synchronous data
port in slot

ss port p.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
A Loss of Loop Timing has
been detected at OCU-DP
port in slot

ss port p.

The specified
OCU-DP port cannot
recover timing from
the received signal on
the local loop.

Check that the CPE
CSU/DSU rate
matches the OCU-DP
rate.

20

month/day/year
hours:minutes:seconds –
Alarm Cleared for Loss of
Loop Timing at OCU-DP
port in slot

ss port p.

Alarm condition no
longer exists.

No action needed.

Advertising