Paradyne T1 T1 Access Mux 926x User Manual

Page 119

Advertising
background image

Setting Up

5-65

9161-A2-GH30-30

April 1998

Table 5-13.

Alarm Options (2 of 3)

Call Retry

Possible Settings: Enable, Disable
Default Setting: Disable

Controls whether an incomplete call (busy, no answer, etc.) from the alarm or SNMP
trap to the COM port’s external device is retried. Attempts the call up to 5 times per
alarm or SNMP trap message.

Enable – Retries incomplete calls with a delay as specified by the Dial-Out Delay Time
configuration option between call attempts.

Disable – Does not retry an incomplete call.

Dial-Out Delay TIme (Min)

Possible Settings: 1 – 10
Default Setting: 5

Specifies the number of minutes to wait between successive dial-out alarms and SNMP
trap messages and call retry attempts in minutes.

1 – 10 – The number of minutes to delay between calls.

Alternate Dial-Out Directory

Possible Settings: None, 1 – 5
Default Setting: None

Specifies whether an incomplete call (busy, or no answer, etc.) from the alarm or SNMP
trap to the COM port’s external device is retried using an alternate telephone number.
Attempts the call up to 5 times per alarm or SNMP trap message.

None – Alternate alarm dial out is not performed.

1 – 5 – Specifies the call directory containing the telephone number to call in the event
that a call cannot be completed to the phone number contained in the Alarm directory.