Paradyne T1 T1 Access Mux 926x User Manual

Page 150

Advertising
background image

Displaying System Information

7-8

9161-A2-GH30-30

April 1998

The Cross Connect Status Field
(bottom) . . .

Indicates . . .

D

ss-p/yy

The DSX-1 on slot

ss, port p, time slot yy

is assigned to the Network Interface time
slot (01 to 24).

D

ss-p/yyr

The DSX-1 on slot

ss, port p, time slot yy

is assigned to the Network Interface time
slot (01 to 24), using Robbed Bit Signaling
(r ).

RsvdAPM

The time slot is assigned to an APM which
is either:

H

failed,

H

removed or not installed, or

H

has been replaced by an APM type that
is not compatible with the configuration.

DDL

The time slot is reserved for a
management path using Direct Data Link
(DDL).

Slot Assignment information. NAM or APM physical slot assignment
information appears below the time slot fields.

The following information is available for viewing.

Physical Slot . . .

Identifies the assigned card type . . .

01 to 14 (based on model)

T1 NAM – T1 NAM.

Empty – The slot is empty.

02 to 05 (based on model)

Sync Data – 4-port synchronous data APM.

DSX-1 – 2-port Dual DSX APM.

E&M Voice – 8-port E&M Voice APM.

FXO Voice – 8-port FXO Voice APM.

FXS Voice – 8-port FXS Voice APM.

OCU (2) – 2-port OCU-DP APM.

OCU (6) – 6-port OCU-DP APM.

Empty – The slot is empty.

Misconfig – The slot contains a misconfigured APM.

Unsupport – The slot contains an unrecognized APM.

Failed – The slot contained an APM that has been
removed or is no longer operational.