Troubleshooting

9-17

9161-A2-GH30-30

April 1998

Table 9-1.

ASCII Alarm Messages (5 of 5)

Message

Priority

What To Do

What It Indicates

month/day/year
hours:minutes:seconds –
Alarm Cleared for Yellow
alarm signal at the
Network1/Network 2
Interface or at the DSX-1
Interface in slot

ss port p.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
A Primary Clock Source
Failure has occurred.

The primary clock
source has failed. The
system is operating
from the secondary
clock source.

1. If the primary clock

was derived from
the network,
contact the network
provider.

2. Check the clock

source. Contact
your service
representative.

22

month/day/year
hours:minutes:seconds –
Alarm Cleared for a
Primary Source Failure.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
A Secondary Clock Source
Failure has occurred.

The secondary clock
source has failed. The
system is operating
from the internal clock.

1. If the secondary

clock was derived
from the network,
contact the network
provider.

2. Check the clock

source. Contact
your service
representative.

21

month/day/year
hours:minutes:seconds –
Alarm Cleared for a
Secondary Source Failure.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
A 64KCC Loop Out of
Frame has been detected
at OCU-DP port in slot

ss

port

p.

A continuous
out-of-frame condition
occurred on the
OCU-DP port for the
identified slot and port.

There is a network
problem with the
fractional portion of
the link carrying this
port’s data. Contact
network provider.

18

month/day/year
hours:minutes:seconds –
Alarm Cleared for a 64KCC
Loop Out Of Frame at
OCU-DP port in slot

ss

port

p.

Alarm condition no
longer exists.

No action needed.