Ocu-dp tests, Sending a latching loopback – Paradyne T1 T1 Access Mux 926x User Manual

Page 219

Advertising
background image

Troubleshooting

9-37

9161-A2-GH30-30

April 1998

"

Procedure

To force signaling:

1. Follow this menu selection sequence:

Main Menu

Test

Voice Port Tests

2. Enter the desired slot and port number.

3. Press PgDn to go to page 2.

4. Enter the desired setting for each field.

5. Highlight Start under Command in the row to send a test. Then, press Return

to start the test.

6. View the length of time that the test has been running in the Results column.

7. Highlight Stop under Command to stop the test.

"

Procedure

To monitor signaling:

1. Follow this menu selection sequence:

Main Menu

Test

Voice Port Tests

2. Enter the desired slot and port number.

3. Press PgDn to go to page 2.

4. Look at the values displayed under the Monitor Signaling portion of the

screen.

OCU-DP Tests

The OCU-DP tests run on the OCU-DP APM’s ports. The procedure to send a
Latching loopback differs from the procedure to start/stop other loopbacks. Both
procedures are described below.

Sending a Latching Loopback

"

Procedure

To send a Latching Loopback:

1. Follow this menu selection sequence:

Main Menu

Test

[OCU-DP Tests]

2. Enter the loopback type:

— For Local: CSU or DSU

— For Remote: CSU, DSU, or OCU

3. Select the code Up or Down.

4. Highlight Send in the Command row. Then, press Return to start the test. The

code will be sent for up to 10 seconds, or until an acknowledgement is
received.

5. View the length of time that the test has been running in the Results column.

6. Send the Down code to stop the loopback.