Sync data apm front panel leds – Paradyne T1 T1 Access Mux 926x User Manual

Page 191

Advertising
background image

OK

1-OK

2-OK

3-OK

4-OK

9109 SYNC D

A

T

A

PORT

97-15679

LEDs

Troubleshooting

9-9

9161-A2-GH30-30

April 1998

The following figure is an example of using the monitor test jacks:

H

DSX MON IN to allow test equipment to nonintrusively monitor the signal
being sent from the T1 access unit to equipment (e.g., a PBX) attached to the
DSX port on the rear of the T1 access unit.

H

DSX MON OUT to allow test equipment to nonintrusively monitor the signal
being sent equipment (e.g., a PBX) attached to the DSX port on the rear of
the T1 access unit.

T1 Access Unit

Internal

Circuitry

Test

Equipment

Front

Rear

Mon In

Mon Out

Rx

Rx

Test

Equipment

PBX

97-15680

Sync Data APM Front Panel LEDs

The Sync Data APM has five LED status indicators.

General Status LED

Label

Indication

Color

What It Means

OK

Power and
Operational
Status

Green

ON

– APM has power and is operational.

OFF – APM is in a local self-test, or there is a

failure.

Port 1, Port 2, Port 3, and Port 4 LEDs

Label

Indication

Color

What It Means

1-OK
2-OK
3-OK
4-OK

Operational
Status

Green

ON

– The interchange circuits for the port

are in the correct state to transmit
and receive data.

OFF – The port is idle. Occurs if the port is

disabled, if an EDL Out of Frame or
EER condition is present, if a DCLB is
active, or if the port is configured to
monitor DTR and/or RTS and the
lead(s) is not asserted.

Advertising