Troubleshooting

9-16

9161-A2-GH30-30

April 1998

Table 9-1.

ASCII Alarm Messages (4 of 5)

Message

Priority

What To Do

What It Indicates

month/day/year
hours:minutes:seconds – A
Loss Of Signal (LOS) has
been detected at the
OCU-DP port in slot

ss

port

p.

LOS condition
detected.

1. Check the cable to

the OCU-DP port.

2. Contact network

provider.

16

month/day/year
hours:minutes:seconds –
Alarm Cleared for a Loss
Of Signal (LOS) at
OCU-DP port in slot

ss

port

p.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
A Module Misconfiguration
condition was detected for
slot

ss.

The identified slot
previously contained a
different type of APM.

Ensure that the APM
installed is the correct
type. If it is not, install
the correct APM type.
The card needs to be
accepted. Refer to the
Technical Reference
for additional
information, if
necessary.

8

month/day/year
hours:minutes:seconds –
Alarm Cleared for the
Module Misconfiguration for
slot

ss.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
Power Supply Alarm
condition detect.

A power supply or fan
tray problem is
detected on the
system.

1. Check that the

power supply or fan
tray is mounted
correctly in the
housing.

2. Contact your

service
representative.

1

month/day/year
hours:minutes:seconds –
Alarm Cleared for Power
Alarm condition.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
Yellow alarm signal
received at the Network
1/Network 2 Interface or at
the DSX-1 Interface in
slot

ss port p.

A Yellow alarm signal
is detected on the
specified Network or
DSX-1 interface.

1. Check the Network

and/or DSX-1
cable.

2. Contact network

provider for
Network interface
problem. Check
equipment for
DSX-1 interface
problem.

9 (Net)
10 (DSX-1)